30
Auto Ping
The section allows you to use an ICMP ping command to check if the attached
device is functioning properly. This function is detailed in the following table:
Enable Put a check in the checkbox to enable this function.
Ping
Address
Enter the IP address of the device to be be pinged in this field.
Interval This field sets how often the specified device is pinged, in second
intervals. Enter a value between 1 and 255.
Fail Count This field sets how many times the device is allowed to fail to respond to
the ping before an action is taken (see below). Enter a value between 1
and 99.
Action This field sets what action is taken if the device fails to respond to a
specified number of pings. Select one of the following actions from the
drop-down menu:
Send email: This sends an email using the SMTP server setting. For
this function to work, you must also enable reports from the SMTP
server. See SMTP Settings, page 41 for details.
Outlet Power Off/On: This resets the power at the KN1000’s power
outlet.
No action: Select this option to do nothing if the specified device fails to
respond.